SY-8258 Specifications
Measurement method Cross-power method (conformance to IEC62044-3)
Measurement mode Bs, Pc, B-H, and µi measurement
Measurement item Characteristics value Maximum magnetic flux density (Bm), maximum magnetic field (Hm), saturation magnetic flux density (Bs), coercive force (Hc), residual magnetic flux density (Br), square ratio (Br/Bm), core loss (Pc, Pcv, Pcm), amplitude permeability (µa), phase angle (θ), AC initial permeability (µiac), inductance (L), Q-factor (Q), [Unit: SI]
Waveform B-H curve and excitation current/inducing voltage/magnetic field/flux density waveforms
Measurement (excitation) frequency 50 Hz to 1 MHz, within ±0.1%
Oscillator output ±3.0 V max.
Magnetic field detection Voltage drop across two ends of non-inductive resistor (1 W ±1%, incorporated in POD)
±5 mA/full-scale to ±5 A/full-scale
Magnetic flux detection Detection of voltage (induced voltage) across two ends of detection coil
±5 mV/full-scale to ±200 V/full-scale
Digitizer resolution 14 bits
Sample connection method 2-coil method (excitation coil, detection coil) or 1-coil method (common excitation/detection coil)
Measurement accuracy Conditions: Standard pod used, temperature held constantly within +23°C ±5°C after preheating for 1 hour following calibration
H, B amplitude measurement: Typical accuracy of within ±3% (80% of range used; range = 50 mA/50 mV or higher)
Phase measurement: Typical accuracy of within ±0.15° (80% of range used; range = 50 mA/50 mV or higher)
Note that the measurement accuracy may differ depending on the characteristics of the sample and the measurement conditions.
Measurement time Approx. 3 seconds (with measurement frequency of 1 kHz or higher and tolerance of ±5% or more)
Display method Color LCD (640 x 240 dots) with backlight
Power supply 100 to 120 V/200 to 240 V AC (selected automatically),
50/60 Hz, power consumption : Approx. 150 VA max.
Weight and dimensions Main unit: Approx. 12 kg, 420 (W) x 177 (H) x 480 (L) ±2 mm (excluding pod)
Environment Performance-guaranteed temperature range: +18°C to +28°C
Operating range: +5°C to +35°C, humidity: 85% RH (+35°C) or less
Preheating time The performance of the instrument is guaranteed when the instrument is held at a constant temperature (±1°C) within the performance-guaranteed temperature range following preheating of at least 60 minutes after power is applied.
Other Optional extras: Built-in LAN interface, built-in GP-IB interface, built-in printer
Provided accessories Power supply cable x 1, SMA-BNC cable x 1, instruction manual x 1