BRINGO II |
BRINGO |
Form
|
DS-8824P |
DS-8824 |
DS-8822P |
DS-8822 |
DS-8814P |
DS-8814can |
DS-8812P |
| Frequency bandwidth |
150MHz |
100MHz |
150MHz |
| Input CH |
4 |
2 |
4 |
2 |
| Display |
5.8-inch LCD display
(backlit EL), Blue color,
320 x 240 dots (115.17 x 86.37 mm) |
| Max. sampling rate |
at CH1, CH3 (2CH): 400MS/s
When 4CH used: 200MS/s |
at CH1 (1CH): 400MS/s
When 2CH used: 200MS/s |
at CH1, CH3 (2CH): 400MS/s
When 4CH used: 200MS/s |
500MS/s |
| Equivalant sampling |
10GS/s |
10GS/s |
25GS/s |
| Peak detect |
5ns |
5ns |
2ns |
| Acquisition memory |
100 k-point/ch |
| Resolution |
8 bits |
| Volt range |
2mV/div to 10V/div |
| Accuracy |
±2% |
| Max. input voltage |
±400V (DC
+ ACpeak) |
| Bandwidth limit |
10MHz |
| Input coupling |
AC, DC, GND |
| Input RC |
1MW±1.5%//20pF±2pF |
| Probe attenuation |
1:1, 10:1, 100:1,
1000:1
(1:1, 10:1, 100:1 are automatically detected) |
| Probe |
SS-0130R (150MHz,
10MW, 12.5pF, 10:1) |
| Calibration signal |
0.6V±1%,
1kHz±0.01% |
| Time base range |
5ns/div to 50s/div |
| Roll mode |
Short [1 k-point/CH
(5 k-point/CH for DS-8812P)]: 100ms/div to 50s/div,
Long [100 k-point]: 2s/div to 50s/div |
| Persistance |
YES |
| Clock accuracy |
50ppm |
| Trigger mode |
Auto, Normal, Single |
| Trigger function |
Edge, Event (COUNT,
BURST, EXTRA, MISSING), TV (NTSC, PAL, SECAM) |
| CAN bus trigger |
NO |
YES*1 |
NO |
| EXT trigger input |
NO |
100mV/div (Fixed) |
NO |
100mV/div (Fixed) |
| External interfaces |
| |
RS-232 |
YES |
| GP-IB |
YES*2 |
NO |
YES*2 |
NO |
YES*2 |
Option:
DS-534 |
| Floppy disk drive |
YES |
NO |
YES |
NO |
YES |
| PC card slot |
YES (ATA card slot) |
| Built-in printer |
YES |
NO |
YES |
NO |
YES |
| Automatic measurement |
Tr, Tf, Vrms, Vmean,
freq, Period, +PW, -PW, Duty, +Peak, -Peak, P-P, Skew |
Top, Base, T-B,
Dt, Area, CVrms, CVmean,
+Oshot, -Oshot, +Pulse, -Pulse |
- |
| Cursor measurement |
DV,
Dt, 1/Dt, V at t simultaneous
4-cursor display available |
| Zoom |
Y-axis: Scaling
within voltage sensitivity setting range,
X-axis: Scaling at center of screen |
| Waveform arithmetic |
CH1+CH2, CH1-CH2,
CH1xCH2, FFT
(CH3+CH4, CH3-CH4, CH3xCH4 for 4CH models) |
| Average |
2 to 256 times
(Short acquisition memory only) |
| Frequency counter |
5-digit, ±0.01%,
1Hz to 150MHz (DS-8814P, DS-8814can: 1Hz to 100MHz) |
| Program mode |
The panel setting
can be changed by dedicated
and
keys |
NO |
| Environmental conditions |
Performance: 10°C
to 35°C,
Operation: 0°C to 40°C, less than 80% RH,
Storage: -10°C to +60°C, less than 80% RH |
| Dimentions |
Approx. 215(W)
x 170(H) x 166(L) mm (excluding protruding parts) |
| Weight |
Approx. 3kg |
Approx. 2.7kg |
Approx. 3kg |
Approx. 2.7kg |
Approx. 3kg |
| Voltage range |
AC 100 to 240 Vrms,
50/60 Hz |
| Power consumption |
100VA |
85VA |
90VA |
75VA |
110VA |
90VA |
| Accessories |
Probe (2 or 4),
Power cable (1), Fuse (2), Operation manual (1), Thermal paper:
for "P" model only (1) |
|