Home>Products>Oscilloscope Accessories>High-voltage Probes HV-P60/HV-P30

High-voltage Probes HV-P60/HV-P30TOP

HV-P60

HV-P60

High-voltage waveforms of up to DC 60 kV, pulse 80 kV measured by oscilloscope

Wide bandwidth, DC to 50 MHz

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications
Maximum input voltage DC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse wave
Bandwidth DC to 50 MHz, within -3 dB
Rise time 7 ns or less (for probes only)
Input RC 1000 MW ±5% //5 pF ±2 pF
Attenuation 2000:1 ±5%
Cable length Approx. 4 m
Connector BNC type
Used for Oscilloscope with input RC: 1 MW, 15 to 50 pF
Size Approx. 88 mm (ø) x 338 mm (L)
Weight Approx. 3.5 kg (including accessories)
Accessories Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag
Options
High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1.
Characteristic curve
Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]

HV-P30


HV-P30
High-voltage probe stand SK-301 (sold separately)

High-voltage waveforms of up to DC 30 kV, pulse 40 kV measured by oscilloscope

Wide bandwidth, DC to 50 MHz

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications
Maximum input voltage DC 30 kV or DC + AC peak*
Single-shot pulse of 40 kV, repetitive signal
Bandwidth DC to 50 MHz, within -3dB
Rise time 7 ns or less (for probes only)
Input RC 100 MW ±5% //7 pF or less
Attenuation 1000:1 ±5%
Cable length Approx. 3 m
Connector BNC type
Used for Oscilloscope with input RC: 1 MW, 15 to 50 pF
Size Approx. 66 mm (ø) x 315 mm (L)
Weight Approx. 3 kg (including accessories)
Accessories Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag
Options High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 30 kV, and the attenuation is 1000:1.
Characteristic curve
Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

Top of this page